forked from luck/tmp_suning_uos_patched
s390/dasd: fix read unit address configuration loop
Read unit address is done for all devices during online processing to read out LCU features. This is also done after disconnect/connect a LCU. Some older storage hardware does not provide the capability to read unit address configuration. This leads to a loop trying to read unit address configuration every 30 seconds. The device is still operational but logs are flooded with error messages. Fix the loop by recognizing a command reject saying that the suborder for ruac is not supported. Signed-off-by: Stefan Haberland <stefan.haberland@de.ibm.com> Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
This commit is contained in:
parent
12d7b1078b
commit
03429f34c2
|
@ -384,6 +384,29 @@ static void _remove_device_from_lcu(struct alias_lcu *lcu,
|
|||
group->next = NULL;
|
||||
};
|
||||
|
||||
static int
|
||||
suborder_not_supported(struct dasd_ccw_req *cqr)
|
||||
{
|
||||
char *sense;
|
||||
char reason;
|
||||
char msg_format;
|
||||
char msg_no;
|
||||
|
||||
sense = dasd_get_sense(&cqr->irb);
|
||||
if (!sense)
|
||||
return 0;
|
||||
|
||||
reason = sense[0];
|
||||
msg_format = (sense[7] & 0xF0);
|
||||
msg_no = (sense[7] & 0x0F);
|
||||
|
||||
/* command reject, Format 0 MSG 4 - invalid parameter */
|
||||
if ((reason == 0x80) && (msg_format == 0x00) && (msg_no == 0x04))
|
||||
return 1;
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
static int read_unit_address_configuration(struct dasd_device *device,
|
||||
struct alias_lcu *lcu)
|
||||
{
|
||||
|
@ -435,6 +458,8 @@ static int read_unit_address_configuration(struct dasd_device *device,
|
|||
|
||||
do {
|
||||
rc = dasd_sleep_on(cqr);
|
||||
if (rc && suborder_not_supported(cqr))
|
||||
return -EOPNOTSUPP;
|
||||
} while (rc && (cqr->retries > 0));
|
||||
if (rc) {
|
||||
spin_lock_irqsave(&lcu->lock, flags);
|
||||
|
@ -521,7 +546,7 @@ static void lcu_update_work(struct work_struct *work)
|
|||
* processing the data
|
||||
*/
|
||||
spin_lock_irqsave(&lcu->lock, flags);
|
||||
if (rc || (lcu->flags & NEED_UAC_UPDATE)) {
|
||||
if ((rc && (rc != -EOPNOTSUPP)) || (lcu->flags & NEED_UAC_UPDATE)) {
|
||||
DBF_DEV_EVENT(DBF_WARNING, device, "could not update"
|
||||
" alias data in lcu (rc = %d), retry later", rc);
|
||||
schedule_delayed_work(&lcu->ruac_data.dwork, 30*HZ);
|
||||
|
|
Loading…
Reference in New Issue