forked from luck/tmp_suning_uos_patched
nvme-fabrics: allow duplicate connections to the discovery controller
The whole point of the discovery controller is that it can accept multiple connections. Additionally the cmic field is not even defined for the discovery controller identify page. Signed-off-by: Hannes Reinecke <hare@suse.com> Reviewed-by: James Smart <james.smart@broadcom.com> Signed-off-by: Christoph Hellwig <hch@lst.de>
This commit is contained in:
parent
461fbc8f0e
commit
181303d035
|
@ -2184,7 +2184,8 @@ static int nvme_init_subsystem(struct nvme_ctrl *ctrl, struct nvme_id_ctrl *id)
|
|||
* Verify that the subsystem actually supports multiple
|
||||
* controllers, else bail out.
|
||||
*/
|
||||
if (nvme_active_ctrls(found) && !(id->cmic & (1 << 1))) {
|
||||
if (!ctrl->opts->discovery_nqn &&
|
||||
nvme_active_ctrls(found) && !(id->cmic & (1 << 1))) {
|
||||
dev_err(ctrl->device,
|
||||
"ignoring ctrl due to duplicate subnqn (%s).\n",
|
||||
found->subnqn);
|
||||
|
|
|
@ -850,6 +850,7 @@ static int nvmf_parse_options(struct nvmf_ctrl_options *opts,
|
|||
if (opts->discovery_nqn) {
|
||||
opts->kato = 0;
|
||||
opts->nr_io_queues = 0;
|
||||
opts->duplicate_connect = true;
|
||||
}
|
||||
if (ctrl_loss_tmo < 0)
|
||||
opts->max_reconnects = -1;
|
||||
|
|
Loading…
Reference in New Issue
Block a user