forked from luck/tmp_suning_uos_patched
mmc: dw_mmc: change the macro name from DTO to DRTO
At Interrupt status register, Bit9 is Data Read Timeout. But we used macro name as the DTO. It could be confused with the Data Transfer Over(DTO)-Bit[3]. It's clearly that is changed the DRTO instead of DTO. Signed-off-by: Jaehoon Chung <jh80.chung@samsung.com> Reviewed-by: James Hogan <james.hogan@imgtec.com> Acked-by: Seungwon Jeon <tgih.jun@samsung.com> Signed-off-by: Chris Ball <cjb@laptop.org>
This commit is contained in:
parent
dcac5fe3cf
commit
3f7eec62ec
@ -39,7 +39,7 @@
|
||||
#include "dw_mmc.h"
|
||||
|
||||
/* Common flag combinations */
|
||||
#define DW_MCI_DATA_ERROR_FLAGS (SDMMC_INT_DTO | SDMMC_INT_DCRC | \
|
||||
#define DW_MCI_DATA_ERROR_FLAGS (SDMMC_INT_DRTO | SDMMC_INT_DCRC | \
|
||||
SDMMC_INT_HTO | SDMMC_INT_SBE | \
|
||||
SDMMC_INT_EBE)
|
||||
#define DW_MCI_CMD_ERROR_FLAGS (SDMMC_INT_RTO | SDMMC_INT_RCRC | \
|
||||
@ -1093,7 +1093,7 @@ static void dw_mci_tasklet_func(unsigned long priv)
|
||||
status = host->data_status;
|
||||
|
||||
if (status & DW_MCI_DATA_ERROR_FLAGS) {
|
||||
if (status & SDMMC_INT_DTO) {
|
||||
if (status & SDMMC_INT_DRTO) {
|
||||
data->error = -ETIMEDOUT;
|
||||
} else if (status & SDMMC_INT_DCRC) {
|
||||
data->error = -EILSEQ;
|
||||
|
@ -98,7 +98,7 @@
|
||||
#define SDMMC_INT_HLE BIT(12)
|
||||
#define SDMMC_INT_FRUN BIT(11)
|
||||
#define SDMMC_INT_HTO BIT(10)
|
||||
#define SDMMC_INT_DTO BIT(9)
|
||||
#define SDMMC_INT_DRTO BIT(9)
|
||||
#define SDMMC_INT_RTO BIT(8)
|
||||
#define SDMMC_INT_DCRC BIT(7)
|
||||
#define SDMMC_INT_RCRC BIT(6)
|
||||
|
Loading…
Reference in New Issue