forked from luck/tmp_suning_uos_patched
NFC: trf7970a: Reread FIFO Status Register when draining FIFO
Receiving an interrupt whose Interrupt Status Register value has only the SRX bit set is supposed to mean that all of the data from the tag has been received. That turns out to not be true so we need to reread the FIFO Status Register to tell if there are any new bytes in the FIFO. If there are, continue receiving them; if there aren't, assume that the receive is complete and pass the data up. Signed-off-by: Mark A. Greer <mgreer@animalcreek.com> Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
This commit is contained in:
parent
bece3c544f
commit
5d8f759424
|
@ -648,6 +648,21 @@ static void trf7970a_drain_fifo(struct trf7970a *trf, u8 status)
|
|||
status = TRF7970A_IRQ_STATUS_SRX;
|
||||
} else {
|
||||
trf->state = TRF7970A_ST_WAIT_FOR_RX_DATA_CONT;
|
||||
|
||||
ret = trf7970a_read(trf, TRF7970A_FIFO_STATUS, &fifo_bytes);
|
||||
if (ret) {
|
||||
trf7970a_send_err_upstream(trf, ret);
|
||||
return;
|
||||
}
|
||||
|
||||
fifo_bytes &= ~TRF7970A_FIFO_STATUS_OVERFLOW;
|
||||
|
||||
/* If there are bytes in the FIFO, set status to '0' so
|
||||
* the if stmt below doesn't fire and the driver will wait
|
||||
* for the trf7970a to generate another RX interrupt.
|
||||
*/
|
||||
if (fifo_bytes)
|
||||
status = 0;
|
||||
}
|
||||
|
||||
no_rx_data:
|
||||
|
|
Loading…
Reference in New Issue
Block a user