USB: additions to the quirk list

this adds some scanners reported to be crashed by autosuspend to
the quirk list.

Signed-off-by: Oliver Neukum <oneukum@suse.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
This commit is contained in:
Oliver Neukum 2007-07-10 14:12:08 +02:00 committed by Greg Kroah-Hartman
parent 8dfe4b1486
commit 6c59649d49

View File

@ -30,12 +30,20 @@
static const struct usb_device_id usb_quirk_list[] = {
/* HP 5300/5370C scanner */
{ USB_DEVICE(0x03f0, 0x0701), .driver_info = USB_QUIRK_STRING_FETCH_255 },
/* Benq S2W 3300U */
{ USB_DEVICE(0x04a5, 0x20b0), .driver_info = USB_QUIRK_NO_AUTOSUSPEND },
/* Seiko Epson Corp. Perfection 1200 */
{ USB_DEVICE(0x04b8, 0x0104), .driver_info = USB_QUIRK_NO_AUTOSUSPEND },
/* Seiko Epson Corp - Perfection 1670 */
{ USB_DEVICE(0x04b8, 0x011f), .driver_info = USB_QUIRK_NO_AUTOSUSPEND },
/* Samsung ML-2510 Series printer */
{ USB_DEVICE(0x04e8, 0x327e), .driver_info = USB_QUIRK_NO_AUTOSUSPEND },
/* Elsa MicroLink 56k (V.250) */
{ USB_DEVICE(0x05cc, 0x2267), .driver_info = USB_QUIRK_NO_AUTOSUSPEND },
/* Ultima Electronics Corp.*/
{ USB_DEVICE(0x05d8, 0x4005), .driver_info = USB_QUIRK_NO_AUTOSUSPEND },
/* Umax [hex] Astra 3400U */
{ USB_DEVICE(0x1606, 0x0060), .driver_info = USB_QUIRK_NO_AUTOSUSPEND },
/* Philips PSC805 audio device */
{ USB_DEVICE(0x0471, 0x0155), .driver_info = USB_QUIRK_RESET_RESUME },