forked from luck/tmp_suning_uos_patched
scsi: docs: convert BusLogic.txt to ReST
Link: https://lore.kernel.org/r/750629b6a5233c85c5391c44d126606b8aabefc8.1583136624.git.mchehab+huawei@kernel.org Acked-by: Khalid Aziz <khalid@gonehiking.org> Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
This commit is contained in:
parent
1d4f8dfe2d
commit
977b899ce3
|
@ -1,6 +1,11 @@
|
|||
BusLogic MultiMaster and FlashPoint SCSI Driver for Linux
|
||||
.. SPDX-License-Identifier: GPL-2.0
|
||||
|
||||
=========================================================
|
||||
BusLogic MultiMaster and FlashPoint SCSI Driver for Linux
|
||||
=========================================================
|
||||
|
||||
Version 2.0.15 for Linux 2.0
|
||||
|
||||
Version 2.1.15 for Linux 2.1
|
||||
|
||||
PRODUCTION RELEASE
|
||||
|
@ -8,13 +13,16 @@
|
|||
17 August 1998
|
||||
|
||||
Leonard N. Zubkoff
|
||||
|
||||
Dandelion Digital
|
||||
|
||||
lnz@dandelion.com
|
||||
|
||||
Copyright 1995-1998 by Leonard N. Zubkoff <lnz@dandelion.com>
|
||||
|
||||
|
||||
INTRODUCTION
|
||||
Introduction
|
||||
============
|
||||
|
||||
BusLogic, Inc. designed and manufactured a variety of high performance SCSI
|
||||
host adapters which share a common programming interface across a diverse
|
||||
|
@ -86,9 +94,11 @@ Contact information for offices in Europe and Japan is available on the Web
|
|||
site.
|
||||
|
||||
|
||||
DRIVER FEATURES
|
||||
Driver Features
|
||||
===============
|
||||
|
||||
o Configuration Reporting and Testing
|
||||
Configuration Reporting and Testing
|
||||
-----------------------------------
|
||||
|
||||
During system initialization, the driver reports extensively on the host
|
||||
adapter hardware configuration, including the synchronous transfer parameters
|
||||
|
@ -130,7 +140,8 @@ o Configuration Reporting and Testing
|
|||
The status of Wide Negotiation, Disconnect/Reconnect, and Tagged Queuing
|
||||
are reported as "Enabled", Disabled", or a sequence of "Y" and "N" letters.
|
||||
|
||||
o Performance Features
|
||||
Performance Features
|
||||
--------------------
|
||||
|
||||
BusLogic SCSI Host Adapters directly implement SCSI-2 Tagged Queuing, and so
|
||||
support has been included in the driver to utilize tagged queuing with any
|
||||
|
@ -150,7 +161,8 @@ o Performance Features
|
|||
queue depth of 1 is selected. Tagged queuing is also disabled for individual
|
||||
target devices if disconnect/reconnect is disabled for that device.
|
||||
|
||||
o Robustness Features
|
||||
Robustness Features
|
||||
-------------------
|
||||
|
||||
The driver implements extensive error recovery procedures. When the higher
|
||||
level parts of the SCSI subsystem request that a timed out command be reset,
|
||||
|
@ -174,7 +186,8 @@ o Robustness Features
|
|||
lock up or crash, and thereby allowing a clean shutdown and restart after the
|
||||
offending component is removed.
|
||||
|
||||
o PCI Configuration Support
|
||||
PCI Configuration Support
|
||||
-------------------------
|
||||
|
||||
On PCI systems running kernels compiled with PCI BIOS support enabled, this
|
||||
driver will interrogate the PCI configuration space and use the I/O port
|
||||
|
@ -184,19 +197,22 @@ o PCI Configuration Support
|
|||
used to disable the ISA compatible I/O port entirely as it is not necessary.
|
||||
The ISA compatible I/O port is disabled by default on the BT-948/958/958D.
|
||||
|
||||
o /proc File System Support
|
||||
/proc File System Support
|
||||
-------------------------
|
||||
|
||||
Copies of the host adapter configuration information together with updated
|
||||
data transfer and error recovery statistics are available through the
|
||||
/proc/scsi/BusLogic/<N> interface.
|
||||
|
||||
o Shared Interrupts Support
|
||||
Shared Interrupts Support
|
||||
-------------------------
|
||||
|
||||
On systems that support shared interrupts, any number of BusLogic Host
|
||||
Adapters may share the same interrupt request channel.
|
||||
|
||||
|
||||
SUPPORTED HOST ADAPTERS
|
||||
Supported Host Adapters
|
||||
=======================
|
||||
|
||||
The following list comprises the supported BusLogic SCSI Host Adapters as of
|
||||
the date of this document. It is recommended that anyone purchasing a BusLogic
|
||||
|
@ -205,6 +221,7 @@ that it is or will be supported.
|
|||
|
||||
FlashPoint Series PCI Host Adapters:
|
||||
|
||||
======================= =============================================
|
||||
FlashPoint LT (BT-930) Ultra SCSI-3
|
||||
FlashPoint LT (BT-930R) Ultra SCSI-3 with RAIDPlus
|
||||
FlashPoint LT (BT-920) Ultra SCSI-3 (BT-930 without BIOS)
|
||||
|
@ -214,15 +231,19 @@ FlashPoint LW (BT-950) Wide Ultra SCSI-3
|
|||
FlashPoint LW (BT-950R) Wide Ultra SCSI-3 with RAIDPlus
|
||||
FlashPoint DW (BT-952) Dual Channel Wide Ultra SCSI-3
|
||||
FlashPoint DW (BT-952R) Dual Channel Wide Ultra SCSI-3 with RAIDPlus
|
||||
======================= =============================================
|
||||
|
||||
MultiMaster "W" Series Host Adapters:
|
||||
|
||||
======= === ==============================
|
||||
BT-948 PCI Ultra SCSI-3
|
||||
BT-958 PCI Wide Ultra SCSI-3
|
||||
BT-958D PCI Wide Differential Ultra SCSI-3
|
||||
======= === ==============================
|
||||
|
||||
MultiMaster "C" Series Host Adapters:
|
||||
|
||||
======== ==== ==============================
|
||||
BT-946C PCI Fast SCSI-2
|
||||
BT-956C PCI Wide Fast SCSI-2
|
||||
BT-956CD PCI Wide Differential Fast SCSI-2
|
||||
|
@ -232,9 +253,11 @@ BT-757C EISA Wide Fast SCSI-2
|
|||
BT-757CD EISA Wide Differential Fast SCSI-2
|
||||
BT-545C ISA Fast SCSI-2
|
||||
BT-540CF ISA Fast SCSI-2
|
||||
======== ==== ==============================
|
||||
|
||||
MultiMaster "S" Series Host Adapters:
|
||||
|
||||
======= ==== ==============================
|
||||
BT-445S VLB Fast SCSI-2
|
||||
BT-747S EISA Fast SCSI-2
|
||||
BT-747D EISA Differential Fast SCSI-2
|
||||
|
@ -244,11 +267,14 @@ BT-545S ISA Fast SCSI-2
|
|||
BT-542D ISA Differential Fast SCSI-2
|
||||
BT-742A EISA SCSI-2 (742A revision H)
|
||||
BT-542B ISA SCSI-2 (542B revision H)
|
||||
======= ==== ==============================
|
||||
|
||||
MultiMaster "A" Series Host Adapters:
|
||||
|
||||
======= ==== ==============================
|
||||
BT-742A EISA SCSI-2 (742A revisions A - G)
|
||||
BT-542B ISA SCSI-2 (542B revisions A - G)
|
||||
======= ==== ==============================
|
||||
|
||||
AMI FastDisk Host Adapters that are true BusLogic MultiMaster clones are also
|
||||
supported by this driver.
|
||||
|
@ -260,9 +286,11 @@ list. The retail kit includes the bare board and manual as well as cabling and
|
|||
driver media and documentation that are not provided with bare boards.
|
||||
|
||||
|
||||
FLASHPOINT INSTALLATION NOTES
|
||||
FlashPoint Installation Notes
|
||||
=============================
|
||||
|
||||
o RAIDPlus Support
|
||||
RAIDPlus Support
|
||||
----------------
|
||||
|
||||
FlashPoint Host Adapters now include RAIDPlus, Mylex's bootable software
|
||||
RAID. RAIDPlus is not supported on Linux, and there are no plans to support
|
||||
|
@ -273,7 +301,8 @@ o RAIDPlus Support
|
|||
than RAIDPlus, so there is little impetus to include RAIDPlus support in the
|
||||
BusLogic driver.
|
||||
|
||||
o Enabling UltraSCSI Transfers
|
||||
Enabling UltraSCSI Transfers
|
||||
----------------------------
|
||||
|
||||
FlashPoint Host Adapters ship with their configuration set to "Factory
|
||||
Default" settings that are conservative and do not allow for UltraSCSI speed
|
||||
|
@ -287,12 +316,14 @@ o Enabling UltraSCSI Transfers
|
|||
the "Optimum Performance" settings are loaded.
|
||||
|
||||
|
||||
BT-948/958/958D INSTALLATION NOTES
|
||||
BT-948/958/958D Installation Notes
|
||||
==================================
|
||||
|
||||
The BT-948/958/958D PCI Ultra SCSI Host Adapters have some features which may
|
||||
require attention in some circumstances when installing Linux.
|
||||
|
||||
o PCI I/O Port Assignments
|
||||
PCI I/O Port Assignments
|
||||
------------------------
|
||||
|
||||
When configured to factory default settings, the BT-948/958/958D will only
|
||||
recognize the PCI I/O port assignments made by the motherboard's PCI BIOS.
|
||||
|
@ -312,7 +343,8 @@ o PCI I/O Port Assignments
|
|||
possible future I/O port conflicts. The older BT-946C/956C/956CD also have
|
||||
this configuration option, but the factory default setting is "Primary".
|
||||
|
||||
o PCI Slot Scanning Order
|
||||
PCI Slot Scanning Order
|
||||
-----------------------
|
||||
|
||||
In systems with multiple BusLogic PCI Host Adapters, the order in which the
|
||||
PCI slots are scanned may appear reversed with the BT-948/958/958D as
|
||||
|
@ -339,7 +371,8 @@ o PCI Slot Scanning Order
|
|||
so as to recognize the host adapters in the same order as they are enumerated
|
||||
by the host adapter's BIOS.
|
||||
|
||||
o Enabling UltraSCSI Transfers
|
||||
Enabling UltraSCSI Transfers
|
||||
----------------------------
|
||||
|
||||
The BT-948/958/958D ship with their configuration set to "Factory Default"
|
||||
settings that are conservative and do not allow for UltraSCSI speed to be
|
||||
|
@ -353,7 +386,8 @@ o Enabling UltraSCSI Transfers
|
|||
"Optimum Performance" settings are loaded.
|
||||
|
||||
|
||||
DRIVER OPTIONS
|
||||
Driver Options
|
||||
==============
|
||||
|
||||
BusLogic Driver Options may be specified either via the Linux Kernel Command
|
||||
Line or via the Loadable Kernel Module Installation Facility. Driver Options
|
||||
|
@ -520,30 +554,34 @@ The following examples demonstrate setting the Queue Depth for Target Devices
|
|||
Devices on the second host adapter to 31, and the Bus Settle Time on the
|
||||
second host adapter to 30 seconds.
|
||||
|
||||
Linux Kernel Command Line:
|
||||
Linux Kernel Command Line::
|
||||
|
||||
linux BusLogic=QueueDepth:[,7,15];QueueDepth:31,BusSettleTime:30
|
||||
|
||||
LILO Linux Boot Loader (in /etc/lilo.conf):
|
||||
LILO Linux Boot Loader (in /etc/lilo.conf)::
|
||||
|
||||
append = "BusLogic=QueueDepth:[,7,15];QueueDepth:31,BusSettleTime:30"
|
||||
|
||||
INSMOD Loadable Kernel Module Installation Facility:
|
||||
INSMOD Loadable Kernel Module Installation Facility::
|
||||
|
||||
insmod BusLogic.o \
|
||||
'BusLogic="QueueDepth:[,7,15];QueueDepth:31,BusSettleTime:30"'
|
||||
|
||||
NOTE: Module Utilities 2.1.71 or later is required for correct parsing
|
||||
|
||||
.. Note::
|
||||
|
||||
Module Utilities 2.1.71 or later is required for correct parsing
|
||||
of driver options containing commas.
|
||||
|
||||
|
||||
DRIVER INSTALLATION
|
||||
Driver Installation
|
||||
===================
|
||||
|
||||
This distribution was prepared for Linux kernel version 2.0.35, but should be
|
||||
compatible with 2.0.4 or any later 2.0 series kernel.
|
||||
|
||||
To install the new BusLogic SCSI driver, you may use the following commands,
|
||||
replacing "/usr/src" with wherever you keep your Linux kernel source tree:
|
||||
replacing "/usr/src" with wherever you keep your Linux kernel source tree::
|
||||
|
||||
cd /usr/src
|
||||
tar -xvzf BusLogic-2.0.15.tar.gz
|
||||
|
@ -557,7 +595,8 @@ Then install "arch/x86/boot/zImage" as your standard kernel, run lilo if
|
|||
appropriate, and reboot.
|
||||
|
||||
|
||||
BUSLOGIC ANNOUNCEMENTS MAILING LIST
|
||||
BusLogic Announcements Mailing List
|
||||
===================================
|
||||
|
||||
The BusLogic Announcements Mailing List provides a forum for informing Linux
|
||||
users of new driver releases and other announcements regarding Linux support
|
|
@ -15,5 +15,6 @@ Linux SCSI Subsystem
|
|||
aic7xxx
|
||||
bfa
|
||||
bnx2fc
|
||||
BusLogic
|
||||
|
||||
scsi_transport_srp/figures
|
||||
|
|
|
@ -3652,7 +3652,7 @@ static bool __init blogic_parse(char **str, char *keyword)
|
|||
selected host adapter.
|
||||
|
||||
The BusLogic Driver Probing Options are described in
|
||||
<file:Documentation/scsi/BusLogic.txt>.
|
||||
<file:Documentation/scsi/BusLogic.rst>.
|
||||
*/
|
||||
|
||||
static int __init blogic_parseopts(char *options)
|
||||
|
|
|
@ -502,7 +502,7 @@ config SCSI_BUSLOGIC
|
|||
This is support for BusLogic MultiMaster and FlashPoint SCSI Host
|
||||
Adapters. Consult the SCSI-HOWTO, available from
|
||||
<http://www.tldp.org/docs.html#howto>, and the files
|
||||
<file:Documentation/scsi/BusLogic.txt> and
|
||||
<file:Documentation/scsi/BusLogic.rst> and
|
||||
<file:Documentation/scsi/FlashPoint.txt> for more information.
|
||||
Note that support for FlashPoint is only available for 32-bit
|
||||
x86 configurations.
|
||||
|
|
Loading…
Reference in New Issue
Block a user