forked from luck/tmp_suning_uos_patched
[media] cec: add proper support for CDC-Only CEC devices
CDC-Only CEC devices are CEC devices that can only handle CDC messages, all other messages are ignored. Add a flag to signal that this is a CDC-Only device and act accordingly. Also add helper functions to identify if a CEC device is configured as a CDC-Only device, a second TV, a switch or a processor, since these variations cannot be determined by the logical address alone. Signed-off-by: Hans Verkuil <hans.verkuil@cisco.com> Signed-off-by: Mauro Carvalho Chehab <mchehab@s-opensource.com>
This commit is contained in:
parent
f5580d8d6f
commit
a69a168a1b
|
@ -1,9 +1,5 @@
|
|||
TODOs:
|
||||
|
||||
- Should CEC_LOG_ADDR_TYPE_SPECIFIC be replaced by TYPE_2ND_TV and TYPE_PROCESSOR?
|
||||
And also TYPE_SWITCH and TYPE_CDC_ONLY in addition to the TYPE_UNREGISTERED?
|
||||
This should give the framework more information about the device type
|
||||
since SPECIFIC and UNREGISTERED give no useful information.
|
||||
- Once this is out of staging this should no longer be a separate
|
||||
config option, instead it should be selected by drivers that want it.
|
||||
- Revisit the IS_REACHABLE(RC_CORE): perhaps the RC_CORE support should
|
||||
|
|
|
@ -1233,7 +1233,8 @@ static int cec_config_thread_func(void *arg)
|
|||
mutex_unlock(&adap->lock);
|
||||
|
||||
for (i = 0; i < las->num_log_addrs; i++) {
|
||||
if (las->log_addr[i] == CEC_LOG_ADDR_INVALID)
|
||||
if (las->log_addr[i] == CEC_LOG_ADDR_INVALID ||
|
||||
(las->flags & CEC_LOG_ADDRS_FL_CDC_ONLY))
|
||||
continue;
|
||||
|
||||
/*
|
||||
|
@ -1355,6 +1356,29 @@ int __cec_s_log_addrs(struct cec_adapter *adap,
|
|||
return 0;
|
||||
}
|
||||
|
||||
if (log_addrs->flags & CEC_LOG_ADDRS_FL_CDC_ONLY) {
|
||||
/*
|
||||
* Sanitize log_addrs fields if a CDC-Only device is
|
||||
* requested.
|
||||
*/
|
||||
log_addrs->num_log_addrs = 1;
|
||||
log_addrs->osd_name[0] = '\0';
|
||||
log_addrs->vendor_id = CEC_VENDOR_ID_NONE;
|
||||
log_addrs->log_addr_type[0] = CEC_LOG_ADDR_TYPE_UNREGISTERED;
|
||||
/*
|
||||
* This is just an internal convention since a CDC-Only device
|
||||
* doesn't have to be a switch. But switches already use
|
||||
* unregistered, so it makes some kind of sense to pick this
|
||||
* as the primary device. Since a CDC-Only device never sends
|
||||
* any 'normal' CEC messages this primary device type is never
|
||||
* sent over the CEC bus.
|
||||
*/
|
||||
log_addrs->primary_device_type[0] = CEC_OP_PRIM_DEVTYPE_SWITCH;
|
||||
log_addrs->all_device_types[0] = 0;
|
||||
log_addrs->features[0][0] = 0;
|
||||
log_addrs->features[0][1] = 0;
|
||||
}
|
||||
|
||||
/* Ensure the osd name is 0-terminated */
|
||||
log_addrs->osd_name[sizeof(log_addrs->osd_name) - 1] = '\0';
|
||||
|
||||
|
@ -1575,6 +1599,11 @@ static int cec_receive_notify(struct cec_adapter *adap, struct cec_msg *msg,
|
|||
|
||||
dprintk(1, "cec_receive_notify: %*ph\n", msg->len, msg->msg);
|
||||
|
||||
/* If this is a CDC-Only device, then ignore any non-CDC messages */
|
||||
if (cec_is_cdc_only(&adap->log_addrs) &&
|
||||
msg->msg[1] != CEC_MSG_CDC_MESSAGE)
|
||||
return 0;
|
||||
|
||||
if (adap->ops->received) {
|
||||
/* Allow drivers to process the message first */
|
||||
if (adap->ops->received(adap, msg) != -ENOMSG)
|
||||
|
|
|
@ -163,7 +163,8 @@ static long cec_adap_s_log_addrs(struct cec_adapter *adap, struct cec_fh *fh,
|
|||
if (copy_from_user(&log_addrs, parg, sizeof(log_addrs)))
|
||||
return -EFAULT;
|
||||
log_addrs.flags &= CEC_LOG_ADDRS_FL_ALLOW_UNREG_FALLBACK |
|
||||
CEC_LOG_ADDRS_FL_ALLOW_RC_PASSTHRU;
|
||||
CEC_LOG_ADDRS_FL_ALLOW_RC_PASSTHRU |
|
||||
CEC_LOG_ADDRS_FL_CDC_ONLY;
|
||||
mutex_lock(&adap->lock);
|
||||
if (!adap->is_configuring &&
|
||||
(!log_addrs.num_log_addrs || !adap->is_configured) &&
|
||||
|
@ -190,6 +191,12 @@ static long cec_transmit(struct cec_adapter *adap, struct cec_fh *fh,
|
|||
return -ENOTTY;
|
||||
if (copy_from_user(&msg, parg, sizeof(msg)))
|
||||
return -EFAULT;
|
||||
|
||||
/* A CDC-Only device can only send CDC messages */
|
||||
if ((adap->log_addrs.flags & CEC_LOG_ADDRS_FL_CDC_ONLY) &&
|
||||
(msg.len == 1 || msg.msg[1] != CEC_MSG_CDC_MESSAGE))
|
||||
return -EINVAL;
|
||||
|
||||
msg.flags &= CEC_MSG_FL_REPLY_TO_FOLLOWERS;
|
||||
mutex_lock(&adap->lock);
|
||||
if (!adap->is_configured)
|
||||
|
|
|
@ -396,6 +396,8 @@ struct cec_log_addrs {
|
|||
#define CEC_LOG_ADDRS_FL_ALLOW_UNREG_FALLBACK (1 << 0)
|
||||
/* Passthrough RC messages to the input subsystem */
|
||||
#define CEC_LOG_ADDRS_FL_ALLOW_RC_PASSTHRU (1 << 1)
|
||||
/* CDC-Only device: supports only CDC messages */
|
||||
#define CEC_LOG_ADDRS_FL_CDC_ONLY (1 << 2)
|
||||
|
||||
/* Events */
|
||||
|
||||
|
@ -1016,4 +1018,54 @@ struct cec_event {
|
|||
#define CEC_OP_HPD_ERROR_OTHER 3
|
||||
#define CEC_OP_HPD_ERROR_NONE_NO_VIDEO 4
|
||||
|
||||
/* End of Messages */
|
||||
|
||||
/* Helper functions to identify the 'special' CEC devices */
|
||||
|
||||
static inline bool cec_is_2nd_tv(const struct cec_log_addrs *las)
|
||||
{
|
||||
/*
|
||||
* It is a second TV if the logical address is 14 or 15 and the
|
||||
* primary device type is a TV.
|
||||
*/
|
||||
return las->num_log_addrs &&
|
||||
las->log_addr[0] >= CEC_LOG_ADDR_SPECIFIC &&
|
||||
las->primary_device_type[0] == CEC_OP_PRIM_DEVTYPE_TV;
|
||||
}
|
||||
|
||||
static inline bool cec_is_processor(const struct cec_log_addrs *las)
|
||||
{
|
||||
/*
|
||||
* It is a processor if the logical address is 12-15 and the
|
||||
* primary device type is a Processor.
|
||||
*/
|
||||
return las->num_log_addrs &&
|
||||
las->log_addr[0] >= CEC_LOG_ADDR_BACKUP_1 &&
|
||||
las->primary_device_type[0] == CEC_OP_PRIM_DEVTYPE_PROCESSOR;
|
||||
}
|
||||
|
||||
static inline bool cec_is_switch(const struct cec_log_addrs *las)
|
||||
{
|
||||
/*
|
||||
* It is a switch if the logical address is 15 and the
|
||||
* primary device type is a Switch and the CDC-Only flag is not set.
|
||||
*/
|
||||
return las->num_log_addrs == 1 &&
|
||||
las->log_addr[0] == CEC_LOG_ADDR_UNREGISTERED &&
|
||||
las->primary_device_type[0] == CEC_OP_PRIM_DEVTYPE_SWITCH &&
|
||||
!(las->flags & CEC_LOG_ADDRS_FL_CDC_ONLY);
|
||||
}
|
||||
|
||||
static inline bool cec_is_cdc_only(const struct cec_log_addrs *las)
|
||||
{
|
||||
/*
|
||||
* It is a CDC-only device if the logical address is 15 and the
|
||||
* primary device type is a Switch and the CDC-Only flag is set.
|
||||
*/
|
||||
return las->num_log_addrs == 1 &&
|
||||
las->log_addr[0] == CEC_LOG_ADDR_UNREGISTERED &&
|
||||
las->primary_device_type[0] == CEC_OP_PRIM_DEVTYPE_SWITCH &&
|
||||
(las->flags & CEC_LOG_ADDRS_FL_CDC_ONLY);
|
||||
}
|
||||
|
||||
#endif
|
||||
|
|
Loading…
Reference in New Issue
Block a user