forked from luck/tmp_suning_uos_patched
mac80211: default to automatic power control
In "mac80211: correct wext transmit power handler" I fixed the wext handler, but forgot to make the default of the user_power_level -1 (aka "auto"), so that now the transmit power is always set to 0, causing associations to time out and similar problems since we're transmitting with very little power. Correct this by correcting the default user_power_level to -1. Signed-off-by: Johannes Berg <johannes@sipsolutions.net> Bisected-by: Niel Lambrechts <niel.lambrechts@gmail.com> Signed-off-by: John W. Linville <linville@tuxdriver.com>
This commit is contained in:
parent
d4c4a9a1bc
commit
c428c89201
|
@ -757,6 +757,7 @@ struct ieee80211_hw *ieee80211_alloc_hw(size_t priv_data_len,
|
|||
local->hw.conf.long_frame_max_tx_count = 4;
|
||||
local->hw.conf.short_frame_max_tx_count = 7;
|
||||
local->hw.conf.radio_enabled = true;
|
||||
local->user_power_level = -1;
|
||||
|
||||
INIT_LIST_HEAD(&local->interfaces);
|
||||
mutex_init(&local->iflist_mtx);
|
||||
|
|
Loading…