forked from luck/tmp_suning_uos_patched
powerpc: Rework pseries machine check handler
Rework pseries machine check handler: - If MSR_RI isn't set, we cannot recover even if the machine check was fully recovered - Rename nonfatal to recovered - Handle RTAS_DISP_LIMITED_RECOVERY - Use BUS_MCEERR_AR instead of BUS_ADRERR - Don't check all the RTAS error log fields when receiving a synchronous machine check. Recent versions of the pseries firmware do not fill them in during a machine check and instead send a follow up error log with the detailed information. If we see a synchronous machine check, and we came from userspace then kill the task. Signed-off-by: Anton Blanchard <anton@samba.org> Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org>
This commit is contained in:
parent
e49b1fae0b
commit
d47d1d8af5
@ -259,31 +259,43 @@ int pSeries_system_reset_exception(struct pt_regs *regs)
|
||||
* Return 1 if corrected (or delivered a signal).
|
||||
* Return 0 if there is nothing we can do.
|
||||
*/
|
||||
static int recover_mce(struct pt_regs *regs, struct rtas_error_log * err)
|
||||
static int recover_mce(struct pt_regs *regs, struct rtas_error_log *err)
|
||||
{
|
||||
int nonfatal = 0;
|
||||
int recovered = 0;
|
||||
|
||||
if (err->disposition == RTAS_DISP_FULLY_RECOVERED) {
|
||||
if (!(regs->msr & MSR_RI)) {
|
||||
/* If MSR_RI isn't set, we cannot recover */
|
||||
recovered = 0;
|
||||
|
||||
} else if (err->disposition == RTAS_DISP_FULLY_RECOVERED) {
|
||||
/* Platform corrected itself */
|
||||
nonfatal = 1;
|
||||
} else if ((regs->msr & MSR_RI) &&
|
||||
user_mode(regs) &&
|
||||
err->severity == RTAS_SEVERITY_ERROR_SYNC &&
|
||||
err->disposition == RTAS_DISP_NOT_RECOVERED &&
|
||||
err->target == RTAS_TARGET_MEMORY &&
|
||||
err->type == RTAS_TYPE_ECC_UNCORR &&
|
||||
!(current->pid == 0 || is_global_init(current))) {
|
||||
/* Kill off a user process with an ECC error */
|
||||
printk(KERN_ERR "MCE: uncorrectable ecc error for pid %d\n",
|
||||
current->pid);
|
||||
/* XXX something better for ECC error? */
|
||||
_exception(SIGBUS, regs, BUS_ADRERR, regs->nip);
|
||||
nonfatal = 1;
|
||||
recovered = 1;
|
||||
|
||||
} else if (err->disposition == RTAS_DISP_LIMITED_RECOVERY) {
|
||||
/* Platform corrected itself but could be degraded */
|
||||
printk(KERN_ERR "MCE: limited recovery, system may "
|
||||
"be degraded\n");
|
||||
recovered = 1;
|
||||
|
||||
} else if (user_mode(regs) && !is_global_init(current) &&
|
||||
err->severity == RTAS_SEVERITY_ERROR_SYNC) {
|
||||
|
||||
/*
|
||||
* If we received a synchronous error when in userspace
|
||||
* kill the task. Firmware may report details of the fail
|
||||
* asynchronously, so we can't rely on the target and type
|
||||
* fields being valid here.
|
||||
*/
|
||||
printk(KERN_ERR "MCE: uncorrectable error, killing task "
|
||||
"%s:%d\n", current->comm, current->pid);
|
||||
|
||||
_exception(SIGBUS, regs, BUS_MCEERR_AR, regs->nip);
|
||||
recovered = 1;
|
||||
}
|
||||
|
||||
log_error((char *)err, ERR_TYPE_RTAS_LOG, 0);
|
||||
|
||||
return nonfatal;
|
||||
return recovered;
|
||||
}
|
||||
|
||||
/*
|
||||
|