tg3: Remove unnecessary phy reset during ethtool commands

The current code unnecessarily resets the phy when we use ethtool to
change the ring parameters or flow control settings. Remove the phy
reset.

Signed-off-by: Nithin Nayak Sujir <nsujir@broadcom.com>
Signed-off-by: Michael Chan <mchan@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Nithin Sujir 2013-04-09 08:48:03 +00:00 committed by David S. Miller
parent f6334bb860
commit f1315d2052

View File

@ -11720,7 +11720,7 @@ static int tg3_set_ringparam(struct net_device *dev, struct ethtool_ringparam *e
if (netif_running(dev)) {
tg3_halt(tp, RESET_KIND_SHUTDOWN, 1);
err = tg3_restart_hw(tp, 1);
err = tg3_restart_hw(tp, 0);
if (!err)
tg3_netif_start(tp);
}
@ -11841,7 +11841,7 @@ static int tg3_set_pauseparam(struct net_device *dev, struct ethtool_pauseparam
if (netif_running(dev)) {
tg3_halt(tp, RESET_KIND_SHUTDOWN, 1);
err = tg3_restart_hw(tp, 1);
err = tg3_restart_hw(tp, 0);
if (!err)
tg3_netif_start(tp);
}