Those get reported in MC0_STATUS, see Table 92, F10h BKDG (31116, rev.
3.28) for more details.
Signed-off-by: Borislav Petkov <borislav.petkov@amd.com>
This is the MCE error code from the MCi_STATUS banks, bits [15:0] which
describe what type of error was encountered: GART TLB, Memory or Bus
error. The semantics of those bits are identical across all MCE banks so
decode those separately, irrespectively of MCE type.
Signed-off-by: Borislav Petkov <borislav.petkov@amd.com>
The MCi_STATUS registers have most field definitions in common so decode
them in the general path. Do not pass ecc_type along and compute it in
__amd64_decode_bus_error instead.
Signed-off-by: Borislav Petkov <borislav.petkov@amd.com>
Move NB decoder along with required defines to EDAC MCE core. Add
registration routines for further decoding of the MCE info in the AMD64
EDAC module.
CC: Andi Kleen <andi@firstfloor.org>
Signed-off-by: Borislav Petkov <borislav.petkov@amd.com>
This is in preparation of adding AMD-specific MCE decoding functionality
to the EDAC core. The error decoding macros originate from the AMD64
EDAC driver albeit in a simplified and cleaned up version here.
While at it, add macros to generate the error description strings and
use them in the error type decoders directly which removes a bunch of
code and makes the decoding functions much more readable. Also, fix
strings and shorten macro names.
Remove superfluous htlink_msgs.
Signed-off-by: Borislav Petkov <borislav.petkov@amd.com>