/* * fs/cifs/inode.c * * Copyright (C) International Business Machines Corp., 2002,2005 * Author(s): Steve French (sfrench@us.ibm.com) * * This library is free software; you can redistribute it and/or modify * it under the terms of the GNU Lesser General Public License as published * by the Free Software Foundation; either version 2.1 of the License, or * (at your option) any later version. * * This library is distributed in the hope that it will be useful, * but WITHOUT ANY WARRANTY; without even the implied warranty of * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See * the GNU Lesser General Public License for more details. * * You should have received a copy of the GNU Lesser General Public License * along with this library; if not, write to the Free Software * Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA */ #include #include #include #include #include #include "cifsfs.h" #include "cifspdu.h" #include "cifsglob.h" #include "cifsproto.h" #include "cifs_debug.h" #include "cifs_fs_sb.h" int cifs_get_inode_info_unix(struct inode **pinode, const unsigned char *search_path, struct super_block *sb, int xid) { int rc = 0; FILE_UNIX_BASIC_INFO findData; struct cifsTconInfo *pTcon; struct inode *inode; struct cifs_sb_info *cifs_sb = CIFS_SB(sb); char *tmp_path; pTcon = cifs_sb->tcon; cFYI(1, (" Getting info on %s ", search_path)); /* could have done a find first instead but this returns more info */ rc = CIFSSMBUnixQPathInfo(xid, pTcon, search_path, &findData, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); /* dump_mem("\nUnixQPathInfo return data", &findData, sizeof(findData)); */ if (rc) { if (rc == -EREMOTE) { tmp_path = kmalloc(strnlen(pTcon->treeName, MAX_TREE_SIZE + 1) + strnlen(search_path, MAX_PATHCONF) + 1, GFP_KERNEL); if (tmp_path == NULL) { return -ENOMEM; } /* have to skip first of the double backslash of UNC name */ strncpy(tmp_path, pTcon->treeName, MAX_TREE_SIZE); strncat(tmp_path, search_path, MAX_PATHCONF); rc = connect_to_dfs_path(xid, pTcon->ses, /* treename + */ tmp_path, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); kfree(tmp_path); /* BB fix up inode etc. */ } else if (rc) { return rc; } } else { struct cifsInodeInfo *cifsInfo; __u32 type = le32_to_cpu(findData.Type); __u64 num_of_bytes = le64_to_cpu(findData.NumOfBytes); __u64 end_of_file = le64_to_cpu(findData.EndOfFile); /* get new inode */ if (*pinode == NULL) { *pinode = new_inode(sb); if (*pinode == NULL) return -ENOMEM; /* Is an i_ino of zero legal? */ /* Are there sanity checks we can use to ensure that the server is really filling in that field? */ if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_SERVER_INUM) { (*pinode)->i_ino = (unsigned long)findData.UniqueId; } /* note ino incremented to unique num in new_inode */ insert_inode_hash(*pinode); } inode = *pinode; cifsInfo = CIFS_I(inode); cFYI(1, (" Old time %ld ", cifsInfo->time)); cifsInfo->time = jiffies; cFYI(1, (" New time %ld ", cifsInfo->time)); /* this is ok to set on every inode revalidate */ atomic_set(&cifsInfo->inUse,1); inode->i_atime = cifs_NTtimeToUnix(le64_to_cpu(findData.LastAccessTime)); inode->i_mtime = cifs_NTtimeToUnix(le64_to_cpu (findData.LastModificationTime)); inode->i_ctime = cifs_NTtimeToUnix(le64_to_cpu(findData.LastStatusChange)); inode->i_mode = le64_to_cpu(findData.Permissions); if (type == UNIX_FILE) { inode->i_mode |= S_IFREG; } else if (type == UNIX_SYMLINK) { inode->i_mode |= S_IFLNK; } else if (type == UNIX_DIR) { inode->i_mode |= S_IFDIR; } else if (type == UNIX_CHARDEV) { inode->i_mode |= S_IFCHR; inode->i_rdev = MKDEV(le64_to_cpu(findData.DevMajor), le64_to_cpu(findData.DevMinor) & MINORMASK); } else if (type == UNIX_BLOCKDEV) { inode->i_mode |= S_IFBLK; inode->i_rdev = MKDEV(le64_to_cpu(findData.DevMajor), le64_to_cpu(findData.DevMinor) & MINORMASK); } else if (type == UNIX_FIFO) { inode->i_mode |= S_IFIFO; } else if (type == UNIX_SOCKET) { inode->i_mode |= S_IFSOCK; } inode->i_uid = le64_to_cpu(findData.Uid); inode->i_gid = le64_to_cpu(findData.Gid); inode->i_nlink = le64_to_cpu(findData.Nlinks); if (is_size_safe_to_change(cifsInfo)) { /* can not safely change the file size here if the client is writing to it due to potential races */ i_size_write(inode, end_of_file); /* blksize needs to be multiple of two. So safer to default to blksize and blkbits set in superblock so 2**blkbits and blksize will match rather than setting to: (pTcon->ses->server->maxBuf - MAX_CIFS_HDR_SIZE) & 0xFFFFFE00;*/ /* This seems incredibly stupid but it turns out that i_blocks is not related to (i_size / i_blksize), instead 512 byte size is required for calculating num blocks */ /* 512 bytes (2**9) is the fake blocksize that must be used */ /* for this calculation */ inode->i_blocks = (512 - 1 + num_of_bytes) >> 9; } if (num_of_bytes < end_of_file) cFYI(1, ("allocation size less than end of file ")); cFYI(1, ("Size %ld and blocks %ld", (unsigned long) inode->i_size, inode->i_blocks)); if (S_ISREG(inode->i_mode)) { cFYI(1, (" File inode ")); inode->i_op = &cifs_file_inode_ops; if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_DIRECT_IO) inode->i_fop = &cifs_file_direct_ops; else inode->i_fop = &cifs_file_ops; if(cifs_sb->mnt_cifs_flags & CIFS_MOUNT_NO_BRL) inode->i_fop->lock = NULL; inode->i_data.a_ops = &cifs_addr_ops; /* check if server can support readpages */ if(pTcon->ses->server->maxBuf < 4096 + MAX_CIFS_HDR_SIZE) inode->i_data.a_ops->readpages = NULL; } else if (S_ISDIR(inode->i_mode)) { cFYI(1, (" Directory inode")); inode->i_op = &cifs_dir_inode_ops; inode->i_fop = &cifs_dir_ops; } else if (S_ISLNK(inode->i_mode)) { cFYI(1, (" Symbolic Link inode ")); inode->i_op = &cifs_symlink_inode_ops; /* tmp_inode->i_fop = */ /* do not need to set to anything */ } else { cFYI(1, (" Init special inode ")); init_special_inode(inode, inode->i_mode, inode->i_rdev); } } return rc; } int cifs_get_inode_info(struct inode **pinode, const unsigned char *search_path, FILE_ALL_INFO *pfindData, struct super_block *sb, int xid) { int rc = 0; struct cifsTconInfo *pTcon; struct inode *inode; struct cifs_sb_info *cifs_sb = CIFS_SB(sb); char *tmp_path; char *buf = NULL; pTcon = cifs_sb->tcon; cFYI(1,("Getting info on %s ", search_path)); if ((pfindData == NULL) && (*pinode != NULL)) { if (CIFS_I(*pinode)->clientCanCacheRead) { cFYI(1,("No need to revalidate cached inode sizes")); return rc; } } /* if file info not passed in then get it from server */ if (pfindData == NULL) { buf = kmalloc(sizeof(FILE_ALL_INFO), GFP_KERNEL); if (buf == NULL) return -ENOMEM; pfindData = (FILE_ALL_INFO *)buf; /* could do find first instead but this returns more info */ rc = CIFSSMBQPathInfo(xid, pTcon, search_path, pfindData, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); /* BB optimize code so we do not make the above call when server claims no NT SMB support and the above call failed at least once - set flag in tcon or mount */ if((rc == -EOPNOTSUPP) || (rc == -EINVAL)) { rc = SMBQueryInformation(xid, pTcon, search_path, pfindData, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); } } /* dump_mem("\nQPathInfo return data",&findData, sizeof(findData)); */ if (rc) { if (rc == -EREMOTE) { tmp_path = kmalloc(strnlen (pTcon->treeName, MAX_TREE_SIZE + 1) + strnlen(search_path, MAX_PATHCONF) + 1, GFP_KERNEL); if (tmp_path == NULL) { kfree(buf); return -ENOMEM; } strncpy(tmp_path, pTcon->treeName, MAX_TREE_SIZE); strncat(tmp_path, search_path, MAX_PATHCONF); rc = connect_to_dfs_path(xid, pTcon->ses, /* treename + */ tmp_path, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); kfree(tmp_path); /* BB fix up inode etc. */ } else if (rc) { kfree(buf); return rc; } } else { struct cifsInodeInfo *cifsInfo; __u32 attr = le32_to_cpu(pfindData->Attributes); /* get new inode */ if (*pinode == NULL) { *pinode = new_inode(sb); if (*pinode == NULL) return -ENOMEM; /* Is an i_ino of zero legal? Can we use that to check if the server supports returning inode numbers? Are there other sanity checks we can use to ensure that the server is really filling in that field? */ /* We can not use the IndexNumber field by default from Windows or Samba (in ALL_INFO buf) but we can request it explicitly. It may not be unique presumably if the server has multiple devices mounted under one share */ /* There may be higher info levels that work but are there Windows server or network appliances for which IndexNumber field is not guaranteed unique? */ #ifdef CONFIG_CIFS_EXPERIMENTAL if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_SERVER_INUM){ int rc1 = 0; __u64 inode_num; rc1 = CIFSGetSrvInodeNumber(xid, pTcon, search_path, &inode_num, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); if (rc1) { cFYI(1,("GetSrvInodeNum rc %d", rc1)); /* BB EOPNOSUPP disable SERVER_INUM? */ } else /* do we need cast or hash to ino? */ (*pinode)->i_ino = inode_num; } /* else ino incremented to unique num in new_inode*/ #endif /* CIFS_EXPERIMENTAL */ insert_inode_hash(*pinode); } inode = *pinode; cifsInfo = CIFS_I(inode); cifsInfo->cifsAttrs = attr; cFYI(1, (" Old time %ld ", cifsInfo->time)); cifsInfo->time = jiffies; cFYI(1, (" New time %ld ", cifsInfo->time)); /* blksize needs to be multiple of two. So safer to default to blksize and blkbits set in superblock so 2**blkbits and blksize will match rather than setting to: (pTcon->ses->server->maxBuf - MAX_CIFS_HDR_SIZE) & 0xFFFFFE00;*/ /* Linux can not store file creation time unfortunately so we ignore it */ inode->i_atime = cifs_NTtimeToUnix(le64_to_cpu(pfindData->LastAccessTime)); inode->i_mtime = cifs_NTtimeToUnix(le64_to_cpu(pfindData->LastWriteTime)); inode->i_ctime = cifs_NTtimeToUnix(le64_to_cpu(pfindData->ChangeTime)); cFYI(0, (" Attributes came in as 0x%x ", attr)); /* set default mode. will override for dirs below */ if (atomic_read(&cifsInfo->inUse) == 0) /* new inode, can safely set these fields */ inode->i_mode = cifs_sb->mnt_file_mode; /* if (attr & ATTR_REPARSE) */ /* We no longer handle these as symlinks because we could not follow them due to the absolute path with drive letter */ if (attr & ATTR_DIRECTORY) { /* override default perms since we do not do byte range locking on dirs */ inode->i_mode = cifs_sb->mnt_dir_mode; inode->i_mode |= S_IFDIR; } else if ((cifs_sb->mnt_cifs_flags & CIFS_MOUNT_UNX_EMUL) && (cifsInfo->cifsAttrs & ATTR_SYSTEM) && /* No need to le64 convert size of zero */ (pfindData->EndOfFile == 0)) { inode->i_mode = cifs_sb->mnt_file_mode; inode->i_mode |= S_IFIFO; /* BB Finish for SFU style symlinks and devies */ /* } else if ((cifs_sb->mnt_cifs_flags & CIFS_MOUNT_UNX_EMUL) && (cifsInfo->cifsAttrs & ATTR_SYSTEM) && ) */ } else { inode->i_mode |= S_IFREG; /* treat the dos attribute of read-only as read-only mode e.g. 555 */ if (cifsInfo->cifsAttrs & ATTR_READONLY) inode->i_mode &= ~(S_IWUGO); /* BB add code here - validate if device or weird share or device type? */ } if (is_size_safe_to_change(cifsInfo)) { /* can not safely change the file size here if the client is writing to it due to potential races */ i_size_write(inode,le64_to_cpu(pfindData->EndOfFile)); /* 512 bytes (2**9) is the fake blocksize that must be used for this calculation */ inode->i_blocks = (512 - 1 + le64_to_cpu( pfindData->AllocationSize)) >> 9; } inode->i_nlink = le32_to_cpu(pfindData->NumberOfLinks); /* BB fill in uid and gid here? with help from winbind? or retrieve from NTFS stream extended attribute */ if (atomic_read(&cifsInfo->inUse) == 0) { inode->i_uid = cifs_sb->mnt_uid; inode->i_gid = cifs_sb->mnt_gid; /* set so we do not keep refreshing these fields with bad data after user has changed them in memory */ atomic_set(&cifsInfo->inUse,1); } if (S_ISREG(inode->i_mode)) { cFYI(1, (" File inode ")); inode->i_op = &cifs_file_inode_ops; if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_DIRECT_IO) inode->i_fop = &cifs_file_direct_ops; else inode->i_fop = &cifs_file_ops; if(cifs_sb->mnt_cifs_flags & CIFS_MOUNT_NO_BRL) inode->i_fop->lock = NULL; inode->i_data.a_ops = &cifs_addr_ops; if(pTcon->ses->server->maxBuf < 4096 + MAX_CIFS_HDR_SIZE) inode->i_data.a_ops->readpages = NULL; } else if (S_ISDIR(inode->i_mode)) { cFYI(1, (" Directory inode ")); inode->i_op = &cifs_dir_inode_ops; inode->i_fop = &cifs_dir_ops; } else if (S_ISLNK(inode->i_mode)) { cFYI(1, (" Symbolic Link inode ")); inode->i_op = &cifs_symlink_inode_ops; } else { init_special_inode(inode, inode->i_mode, inode->i_rdev); } } kfree(buf); return rc; } /* gets root inode */ void cifs_read_inode(struct inode *inode) { int xid; struct cifs_sb_info *cifs_sb; cifs_sb = CIFS_SB(inode->i_sb); xid = GetXid(); if (cifs_sb->tcon->ses->capabilities & CAP_UNIX) cifs_get_inode_info_unix(&inode, "", inode->i_sb,xid); else cifs_get_inode_info(&inode, "", NULL, inode->i_sb,xid); /* can not call macro FreeXid here since in a void func */ _FreeXid(xid); } int cifs_unlink(struct inode *inode, struct dentry *direntry) { int rc = 0; int xid; struct cifs_sb_info *cifs_sb; struct cifsTconInfo *pTcon; char *full_path = NULL; struct cifsInodeInfo *cifsInode; FILE_BASIC_INFO *pinfo_buf; cFYI(1, (" cifs_unlink, inode = 0x%p with ", inode)); xid = GetXid(); cifs_sb = CIFS_SB(inode->i_sb); pTcon = cifs_sb->tcon; /* Unlink can be called from rename so we can not grab the sem here since we deadlock otherwise */ /* down(&direntry->d_sb->s_vfs_rename_sem);*/ full_path = build_path_from_dentry(direntry); /* up(&direntry->d_sb->s_vfs_rename_sem);*/ if (full_path == NULL) { FreeXid(xid); return -ENOMEM; } rc = CIFSSMBDelFile(xid, pTcon, full_path, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); if (!rc) { if (direntry->d_inode) direntry->d_inode->i_nlink--; } else if (rc == -ENOENT) { d_drop(direntry); } else if (rc == -ETXTBSY) { int oplock = FALSE; __u16 netfid; rc = CIFSSMBOpen(xid, pTcon, full_path, FILE_OPEN, DELETE, CREATE_NOT_DIR | CREATE_DELETE_ON_CLOSE, &netfid, &oplock, NULL, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); if (rc==0) { CIFSSMBRenameOpenFile(xid, pTcon, netfid, NULL, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); CIFSSMBClose(xid, pTcon, netfid); if (direntry->d_inode) direntry->d_inode->i_nlink--; } } else if (rc == -EACCES) { /* try only if r/o attribute set in local lookup data? */ pinfo_buf = kmalloc(sizeof(FILE_BASIC_INFO), GFP_KERNEL); if (pinfo_buf) { memset(pinfo_buf, 0, sizeof(FILE_BASIC_INFO)); /* ATTRS set to normal clears r/o bit */ pinfo_buf->Attributes = cpu_to_le32(ATTR_NORMAL); if (!(pTcon->ses->flags & CIFS_SES_NT4)) rc = CIFSSMBSetTimes(xid, pTcon, full_path, pinfo_buf, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); else rc = -EOPNOTSUPP; if (rc == -EOPNOTSUPP) { int oplock = FALSE; __u16 netfid; /* rc = CIFSSMBSetAttrLegacy(xid, pTcon, full_path, (__u16)ATTR_NORMAL, cifs_sb->local_nls); For some strange reason it seems that NT4 eats the old setattr call without actually setting the attributes so on to the third attempted workaround */ /* BB could scan to see if we already have it open and pass in pid of opener to function */ rc = CIFSSMBOpen(xid, pTcon, full_path, FILE_OPEN, SYNCHRONIZE | FILE_WRITE_ATTRIBUTES, 0, &netfid, &oplock, NULL, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); if (rc==0) { rc = CIFSSMBSetFileTimes(xid, pTcon, pinfo_buf, netfid); CIFSSMBClose(xid, pTcon, netfid); } } kfree(pinfo_buf); } if (rc==0) { rc = CIFSSMBDelFile(xid, pTcon, full_path, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); if (!rc) { if (direntry->d_inode) direntry->d_inode->i_nlink--; } else if (rc == -ETXTBSY) { int oplock = FALSE; __u16 netfid; rc = CIFSSMBOpen(xid, pTcon, full_path, FILE_OPEN, DELETE, CREATE_NOT_DIR | CREATE_DELETE_ON_CLOSE, &netfid, &oplock, NULL, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); if (rc==0) { CIFSSMBRenameOpenFile(xid, pTcon, netfid, NULL, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); CIFSSMBClose(xid, pTcon, netfid); if (direntry->d_inode) direntry->d_inode->i_nlink--; } /* BB if rc = -ETXTBUSY goto the rename logic BB */ } } } if (direntry->d_inode) { cifsInode = CIFS_I(direntry->d_inode); cifsInode->time = 0; /* will force revalidate to get info when needed */ direntry->d_inode->i_ctime = current_fs_time(inode->i_sb); } inode->i_ctime = inode->i_mtime = current_fs_time(inode->i_sb); cifsInode = CIFS_I(inode); cifsInode->time = 0; /* force revalidate of dir as well */ kfree(full_path); FreeXid(xid); return rc; } int cifs_mkdir(struct inode *inode, struct dentry *direntry, int mode) { int rc = 0; int xid; struct cifs_sb_info *cifs_sb; struct cifsTconInfo *pTcon; char *full_path = NULL; struct inode *newinode = NULL; cFYI(1, ("In cifs_mkdir, mode = 0x%x inode = 0x%p ", mode, inode)); xid = GetXid(); cifs_sb = CIFS_SB(inode->i_sb); pTcon = cifs_sb->tcon; down(&inode->i_sb->s_vfs_rename_sem); full_path = build_path_from_dentry(direntry); up(&inode->i_sb->s_vfs_rename_sem); if (full_path == NULL) { FreeXid(xid); return -ENOMEM; } /* BB add setting the equivalent of mode via CreateX w/ACLs */ rc = CIFSSMBMkDir(xid, pTcon, full_path, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); if (rc) { cFYI(1, ("cifs_mkdir returned 0x%x ", rc)); d_drop(direntry); } else { inode->i_nlink++; if (pTcon->ses->capabilities & CAP_UNIX) rc = cifs_get_inode_info_unix(&newinode, full_path, inode->i_sb,xid); else rc = cifs_get_inode_info(&newinode, full_path, NULL, inode->i_sb,xid); if (pTcon->nocase) direntry->d_op = &cifs_ci_dentry_ops; else direntry->d_op = &cifs_dentry_ops; d_instantiate(direntry, newinode); if (direntry->d_inode) direntry->d_inode->i_nlink = 2; if (cifs_sb->tcon->ses->capabilities & CAP_UNIX) if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_SET_UID) { CIFSSMBUnixSetPerms(xid, pTcon, full_path, mode, (__u64)current->euid, (__u64)current->egid, 0 /* dev_t */, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); } else { CIFSSMBUnixSetPerms(xid, pTcon, full_path, mode, (__u64)-1, (__u64)-1, 0 /* dev_t */, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); } else { /* BB to be implemented via Windows secrty descriptors eg CIFSSMBWinSetPerms(xid, pTcon, full_path, mode, -1, -1, local_nls); */ } } kfree(full_path); FreeXid(xid); return rc; } int cifs_rmdir(struct inode *inode, struct dentry *direntry) { int rc = 0; int xid; struct cifs_sb_info *cifs_sb; struct cifsTconInfo *pTcon; char *full_path = NULL; struct cifsInodeInfo *cifsInode; cFYI(1, (" cifs_rmdir, inode = 0x%p with ", inode)); xid = GetXid(); cifs_sb = CIFS_SB(inode->i_sb); pTcon = cifs_sb->tcon; down(&inode->i_sb->s_vfs_rename_sem); full_path = build_path_from_dentry(direntry); up(&inode->i_sb->s_vfs_rename_sem); if (full_path == NULL) { FreeXid(xid); return -ENOMEM; } rc = CIFSSMBRmDir(xid, pTcon, full_path, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); if (!rc) { inode->i_nlink--; i_size_write(direntry->d_inode,0); direntry->d_inode->i_nlink = 0; } cifsInode = CIFS_I(direntry->d_inode); cifsInode->time = 0; /* force revalidate to go get info when needed */ direntry->d_inode->i_ctime = inode->i_ctime = inode->i_mtime = current_fs_time(inode->i_sb); kfree(full_path); FreeXid(xid); return rc; } int cifs_rename(struct inode *source_inode, struct dentry *source_direntry, struct inode *target_inode, struct dentry *target_direntry) { char *fromName; char *toName; struct cifs_sb_info *cifs_sb_source; struct cifs_sb_info *cifs_sb_target; struct cifsTconInfo *pTcon; int xid; int rc = 0; xid = GetXid(); cifs_sb_target = CIFS_SB(target_inode->i_sb); cifs_sb_source = CIFS_SB(source_inode->i_sb); pTcon = cifs_sb_source->tcon; if (pTcon != cifs_sb_target->tcon) { FreeXid(xid); return -EXDEV; /* BB actually could be allowed if same server, but different share. Might eventually add support for this */ } /* we already have the rename sem so we do not need to grab it again here to protect the path integrity */ fromName = build_path_from_dentry(source_direntry); toName = build_path_from_dentry(target_direntry); if ((fromName == NULL) || (toName == NULL)) { rc = -ENOMEM; goto cifs_rename_exit; } rc = CIFSSMBRename(xid, pTcon, fromName, toName, cifs_sb_source->local_nls, cifs_sb_source->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); if (rc == -EEXIST) { /* check if they are the same file because rename of hardlinked files is a noop */ FILE_UNIX_BASIC_INFO *info_buf_source; FILE_UNIX_BASIC_INFO *info_buf_target; info_buf_source = kmalloc(2 * sizeof(FILE_UNIX_BASIC_INFO), GFP_KERNEL); if (info_buf_source != NULL) { info_buf_target = info_buf_source + 1; rc = CIFSSMBUnixQPathInfo(xid, pTcon, fromName, info_buf_source, cifs_sb_source->local_nls, cifs_sb_source->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); if (rc == 0) { rc = CIFSSMBUnixQPathInfo(xid, pTcon, toName, info_buf_target, cifs_sb_target->local_nls, /* remap based on source sb */ cifs_sb_source->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); } if ((rc == 0) && (info_buf_source->UniqueId == info_buf_target->UniqueId)) { /* do not rename since the files are hardlinked which is a noop */ } else { /* we either can not tell the files are hardlinked (as with Windows servers) or files are not hardlinked so delete the target manually before renaming to follow POSIX rather than Windows semantics */ cifs_unlink(target_inode, target_direntry); rc = CIFSSMBRename(xid, pTcon, fromName, toName, cifs_sb_source->local_nls, cifs_sb_source->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); } kfree(info_buf_source); } /* if we can not get memory just leave rc as EEXIST */ } if (rc) { cFYI(1, ("rename rc %d", rc)); } if ((rc == -EIO) || (rc == -EEXIST)) { int oplock = FALSE; __u16 netfid; /* BB FIXME Is Generic Read correct for rename? */ /* if renaming directory - we should not say CREATE_NOT_DIR, need to test renaming open directory, also GENERIC_READ might not right be right access to request */ rc = CIFSSMBOpen(xid, pTcon, fromName, FILE_OPEN, GENERIC_READ, CREATE_NOT_DIR, &netfid, &oplock, NULL, cifs_sb_source->local_nls, cifs_sb_source->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); if (rc==0) { CIFSSMBRenameOpenFile(xid, pTcon, netfid, toName, cifs_sb_source->local_nls, cifs_sb_source->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); CIFSSMBClose(xid, pTcon, netfid); } } cifs_rename_exit: kfree(fromName); kfree(toName); FreeXid(xid); return rc; } int cifs_revalidate(struct dentry *direntry) { int xid; int rc = 0; char *full_path; struct cifs_sb_info *cifs_sb; struct cifsInodeInfo *cifsInode; loff_t local_size; struct timespec local_mtime; int invalidate_inode = FALSE; if (direntry->d_inode == NULL) return -ENOENT; cifsInode = CIFS_I(direntry->d_inode); if (cifsInode == NULL) return -ENOENT; /* no sense revalidating inode info on file that no one can write */ if (CIFS_I(direntry->d_inode)->clientCanCacheRead) return rc; xid = GetXid(); cifs_sb = CIFS_SB(direntry->d_sb); /* can not safely grab the rename sem here if rename calls revalidate since that would deadlock */ full_path = build_path_from_dentry(direntry); if (full_path == NULL) { FreeXid(xid); return -ENOMEM; } cFYI(1, ("Revalidate: %s inode 0x%p count %d dentry: 0x%p d_time %ld " "jiffies %ld", full_path, direntry->d_inode, direntry->d_inode->i_count.counter, direntry, direntry->d_time, jiffies)); if (cifsInode->time == 0) { /* was set to zero previously to force revalidate */ } else if (time_before(jiffies, cifsInode->time + HZ) && lookupCacheEnabled) { if ((S_ISREG(direntry->d_inode->i_mode) == 0) || (direntry->d_inode->i_nlink == 1)) { kfree(full_path); FreeXid(xid); return rc; } else { cFYI(1, ("Have to revalidate file due to hardlinks")); } } /* save mtime and size */ local_mtime = direntry->d_inode->i_mtime; local_size = direntry->d_inode->i_size; if (cifs_sb->tcon->ses->capabilities & CAP_UNIX) { rc = cifs_get_inode_info_unix(&direntry->d_inode, full_path, direntry->d_sb,xid); if (rc) { cFYI(1, ("error on getting revalidate info %d", rc)); /* if (rc != -ENOENT) rc = 0; */ /* BB should we cache info on certain errors? */ } } else { rc = cifs_get_inode_info(&direntry->d_inode, full_path, NULL, direntry->d_sb,xid); if (rc) { cFYI(1, ("error on getting revalidate info %d", rc)); /* if (rc != -ENOENT) rc = 0; */ /* BB should we cache info on certain errors? */ } } /* should we remap certain errors, access denied?, to zero */ /* if not oplocked, we invalidate inode pages if mtime or file size had changed on server */ if (timespec_equal(&local_mtime,&direntry->d_inode->i_mtime) && (local_size == direntry->d_inode->i_size)) { cFYI(1, ("cifs_revalidate - inode unchanged")); } else { /* file may have changed on server */ if (cifsInode->clientCanCacheRead) { /* no need to invalidate inode pages since we were the only ones who could have modified the file and the server copy is staler than ours */ } else { invalidate_inode = TRUE; } } /* can not grab this sem since kernel filesys locking documentation indicates i_sem may be taken by the kernel on lookup and rename which could deadlock if we grab the i_sem here as well */ /* down(&direntry->d_inode->i_sem);*/ /* need to write out dirty pages here */ if (direntry->d_inode->i_mapping) { /* do we need to lock inode until after invalidate completes below? */ filemap_fdatawrite(direntry->d_inode->i_mapping); } if (invalidate_inode) { if (direntry->d_inode->i_mapping) filemap_fdatawait(direntry->d_inode->i_mapping); /* may eventually have to do this for open files too */ if (list_empty(&(cifsInode->openFileList))) { /* Has changed on server - flush read ahead pages */ cFYI(1, ("Invalidating read ahead data on " "closed file")); invalidate_remote_inode(direntry->d_inode); } } /* up(&direntry->d_inode->i_sem); */ kfree(full_path); FreeXid(xid); return rc; } int cifs_getattr(struct vfsmount *mnt, struct dentry *dentry, struct kstat *stat) { int err = cifs_revalidate(dentry); if (!err) generic_fillattr(dentry->d_inode, stat); return err; } static int cifs_truncate_page(struct address_space *mapping, loff_t from) { pgoff_t index = from >> PAGE_CACHE_SHIFT; unsigned offset = from & (PAGE_CACHE_SIZE - 1); struct page *page; char *kaddr; int rc = 0; page = grab_cache_page(mapping, index); if (!page) return -ENOMEM; kaddr = kmap_atomic(page, KM_USER0); memset(kaddr + offset, 0, PAGE_CACHE_SIZE - offset); flush_dcache_page(page); kunmap_atomic(kaddr, KM_USER0); unlock_page(page); page_cache_release(page); return rc; } int cifs_setattr(struct dentry *direntry, struct iattr *attrs) { int xid; struct cifs_sb_info *cifs_sb; struct cifsTconInfo *pTcon; char *full_path = NULL; int rc = -EACCES; int found = FALSE; struct cifsFileInfo *open_file = NULL; FILE_BASIC_INFO time_buf; int set_time = FALSE; __u64 mode = 0xFFFFFFFFFFFFFFFFULL; __u64 uid = 0xFFFFFFFFFFFFFFFFULL; __u64 gid = 0xFFFFFFFFFFFFFFFFULL; struct cifsInodeInfo *cifsInode; struct list_head *tmp; xid = GetXid(); cFYI(1, (" In cifs_setattr, name = %s attrs->iavalid 0x%x ", direntry->d_name.name, attrs->ia_valid)); cifs_sb = CIFS_SB(direntry->d_inode->i_sb); pTcon = cifs_sb->tcon; down(&direntry->d_sb->s_vfs_rename_sem); full_path = build_path_from_dentry(direntry); up(&direntry->d_sb->s_vfs_rename_sem); if (full_path == NULL) { FreeXid(xid); return -ENOMEM; } cifsInode = CIFS_I(direntry->d_inode); /* BB check if we need to refresh inode from server now ? BB */ /* need to flush data before changing file size on server */ filemap_fdatawrite(direntry->d_inode->i_mapping); filemap_fdatawait(direntry->d_inode->i_mapping); if (attrs->ia_valid & ATTR_SIZE) { read_lock(&GlobalSMBSeslock); /* To avoid spurious oplock breaks from server, in the case of inodes that we already have open, avoid doing path based setting of file size if we can do it by handle. This keeps our caching token (oplock) and avoids timeouts when the local oplock break takes longer to flush writebehind data than the SMB timeout for the SetPathInfo request would allow */ list_for_each(tmp, &cifsInode->openFileList) { open_file = list_entry(tmp, struct cifsFileInfo, flist); /* We check if file is open for writing first */ if ((open_file->pfile) && ((open_file->pfile->f_flags & O_RDWR) || (open_file->pfile->f_flags & O_WRONLY))) { if (open_file->invalidHandle == FALSE) { /* we found a valid, writeable network file handle to use to try to set the file size */ __u16 nfid = open_file->netfid; __u32 npid = open_file->pid; read_unlock(&GlobalSMBSeslock); found = TRUE; rc = CIFSSMBSetFileSize(xid, pTcon, attrs->ia_size, nfid, npid, FALSE); cFYI(1, ("SetFileSize by handle " "(setattrs) rc = %d", rc)); /* Do not need reopen and retry on EAGAIN since we will retry by pathname below */ /* now that we found one valid file handle no sense continuing to loop trying others, so break here */ /* if(rc == -EINVAL) { int bytes_written; rc = CIFSSMBWrite(xid, pTcon, nfid, 0, attrs->ia_size, &bytes_written, NULL, NULL, long_op); } */ break; } } } if (found == FALSE) read_unlock(&GlobalSMBSeslock); if (rc != 0) { /* Set file size by pathname rather than by handle either because no valid, writeable file handle for it was found or because there was an error setting it by handle */ rc = CIFSSMBSetEOF(xid, pTcon, full_path, attrs->ia_size, FALSE, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); cFYI(1, (" SetEOF by path (setattrs) rc = %d", rc)); /* if(rc == -EINVAL) old_style_set_eof_via_write(xid, pTcon, full_path, attrs->ia_size, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR);*/ } /* Server is ok setting allocation size implicitly - no need to call: CIFSSMBSetEOF(xid, pTcon, full_path, attrs->ia_size, TRUE, cifs_sb->local_nls); */ if (rc == 0) { rc = vmtruncate(direntry->d_inode, attrs->ia_size); cifs_truncate_page(direntry->d_inode->i_mapping, direntry->d_inode->i_size); } } if (attrs->ia_valid & ATTR_UID) { cFYI(1, (" CIFS - UID changed to %d", attrs->ia_uid)); uid = attrs->ia_uid; /* entry->uid = cpu_to_le16(attr->ia_uid); */ } if (attrs->ia_valid & ATTR_GID) { cFYI(1, (" CIFS - GID changed to %d", attrs->ia_gid)); gid = attrs->ia_gid; /* entry->gid = cpu_to_le16(attr->ia_gid); */ } time_buf.Attributes = 0; if (attrs->ia_valid & ATTR_MODE) { cFYI(1, (" CIFS - Mode changed to 0x%x", attrs->ia_mode)); mode = attrs->ia_mode; /* entry->mode = cpu_to_le16(attr->ia_mode); */ } if ((cifs_sb->tcon->ses->capabilities & CAP_UNIX) && (attrs->ia_valid & (ATTR_MODE | ATTR_GID | ATTR_UID))) rc = CIFSSMBUnixSetPerms(xid, pTcon, full_path, mode, uid, gid, 0 /* dev_t */, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); else if (attrs->ia_valid & ATTR_MODE) { if ((mode & S_IWUGO) == 0) /* not writeable */ { if ((cifsInode->cifsAttrs & ATTR_READONLY) == 0) time_buf.Attributes = cpu_to_le32(cifsInode->cifsAttrs | ATTR_READONLY); } else if ((mode & S_IWUGO) == S_IWUGO) { if (cifsInode->cifsAttrs & ATTR_READONLY) time_buf.Attributes = cpu_to_le32(cifsInode->cifsAttrs & (~ATTR_READONLY)); } /* BB to be implemented - via Windows security descriptors or streams */ /* CIFSSMBWinSetPerms(xid, pTcon, full_path, mode, uid, gid, cifs_sb->local_nls); */ } if (attrs->ia_valid & ATTR_ATIME) { set_time = TRUE; time_buf.LastAccessTime = cpu_to_le64(cifs_UnixTimeToNT(attrs->ia_atime)); } else time_buf.LastAccessTime = 0; if (attrs->ia_valid & ATTR_MTIME) { set_time = TRUE; time_buf.LastWriteTime = cpu_to_le64(cifs_UnixTimeToNT(attrs->ia_mtime)); } else time_buf.LastWriteTime = 0; if (attrs->ia_valid & ATTR_CTIME) { set_time = TRUE; cFYI(1, (" CIFS - CTIME changed ")); /* BB probably no need */ time_buf.ChangeTime = cpu_to_le64(cifs_UnixTimeToNT(attrs->ia_ctime)); } else time_buf.ChangeTime = 0; if (set_time || time_buf.Attributes) { /* BB what if setting one attribute fails (such as size) but time setting works? */ time_buf.CreationTime = 0; /* do not change */ /* In the future we should experiment - try setting timestamps via Handle (SetFileInfo) instead of by path */ if (!(pTcon->ses->flags & CIFS_SES_NT4)) rc = CIFSSMBSetTimes(xid, pTcon, full_path, &time_buf, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); else rc = -EOPNOTSUPP; if (rc == -EOPNOTSUPP) { int oplock = FALSE; __u16 netfid; cFYI(1, ("calling SetFileInfo since SetPathInfo for " "times not supported by this server")); /* BB we could scan to see if we already have it open and pass in pid of opener to function */ rc = CIFSSMBOpen(xid, pTcon, full_path, FILE_OPEN, SYNCHRONIZE | FILE_WRITE_ATTRIBUTES, CREATE_NOT_DIR, &netfid, &oplock, NULL, cifs_sb->local_nls, cifs_sb->mnt_cifs_flags & CIFS_MOUNT_MAP_SPECIAL_CHR); if (rc==0) { rc = CIFSSMBSetFileTimes(xid, pTcon, &time_buf, netfid); CIFSSMBClose(xid, pTcon, netfid); } else { /* BB For even older servers we could convert time_buf into old DOS style which uses two second granularity */ /* rc = CIFSSMBSetTimesLegacy(xid, pTcon, full_path, &time_buf, cifs_sb->local_nls); */ } } } /* do not need local check to inode_check_ok since the server does that */ if (!rc) rc = inode_setattr(direntry->d_inode, attrs); kfree(full_path); FreeXid(xid); return rc; } void cifs_delete_inode(struct inode *inode) { cFYI(1, ("In cifs_delete_inode, inode = 0x%p ", inode)); /* may have to add back in if and when safe distributed caching of directories added e.g. via FindNotify */ }