forked from luck/tmp_suning_uos_patched
b968279625
Document amd_energy driver with energy sensors supported by it. Cc: Guenter Roeck <linux@roeck-us.net> Signed-off-by: Naveen Krishna Chatradhi <nchatrad@amd.com> Link: https://lore.kernel.org/r/20200519155011.56184-2-nchatrad@amd.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
110 lines
3.4 KiB
ReStructuredText
110 lines
3.4 KiB
ReStructuredText
.. SPDX-License-Identifier: GPL-2.0
|
|
|
|
Kernel driver amd_energy
|
|
==========================
|
|
|
|
Supported chips:
|
|
|
|
* AMD Family 17h Processors
|
|
|
|
Prefix: 'amd_energy'
|
|
|
|
Addresses used: RAPL MSRs
|
|
|
|
Datasheets:
|
|
|
|
- Processor Programming Reference (PPR) for AMD Family 17h Model 01h, Revision B1 Processors
|
|
|
|
https://developer.amd.com/wp-content/resources/55570-B1_PUB.zip
|
|
|
|
- Preliminary Processor Programming Reference (PPR) for AMD Family 17h Model 31h, Revision B0 Processors
|
|
|
|
https://developer.amd.com/wp-content/resources/56176_ppr_Family_17h_Model_71h_B0_pub_Rev_3.06.zip
|
|
|
|
Author: Naveen Krishna Chatradhi <nchatrad@amd.com>
|
|
|
|
Description
|
|
-----------
|
|
|
|
The Energy driver exposes the energy counters that are
|
|
reported via the Running Average Power Limit (RAPL)
|
|
Model-specific Registers (MSRs) via the hardware monitor
|
|
(HWMON) sysfs interface.
|
|
|
|
1. Power, Energy and Time Units
|
|
MSR_RAPL_POWER_UNIT/ C001_0299:
|
|
shared with all cores in the socket
|
|
|
|
2. Energy consumed by each Core
|
|
MSR_CORE_ENERGY_STATUS/ C001_029A:
|
|
32-bitRO, Accumulator, core-level power reporting
|
|
|
|
3. Energy consumed by Socket
|
|
MSR_PACKAGE_ENERGY_STATUS/ C001_029B:
|
|
32-bitRO, Accumulator, socket-level power reporting,
|
|
shared with all cores in socket
|
|
|
|
These registers are updated every 1ms and cleared on
|
|
reset of the system.
|
|
|
|
Note: If SMT is enabled, Linux enumerates all threads as cpus.
|
|
Since, the energy status registers are accessed at core level,
|
|
reading those registers from the sibling threads would result
|
|
in duplicate values. Hence, energy counter entries are not
|
|
populated for the siblings.
|
|
|
|
Energy Caluclation
|
|
------------------
|
|
|
|
Energy information (in Joules) is based on the multiplier,
|
|
1/2^ESU; where ESU is an unsigned integer read from
|
|
MSR_RAPL_POWER_UNIT register. Default value is 10000b,
|
|
indicating energy status unit is 15.3 micro-Joules increment.
|
|
|
|
Reported values are scaled as per the formula
|
|
|
|
scaled value = ((1/2^ESU) * (Raw value) * 1000000UL) in uJoules
|
|
|
|
Users calculate power for a given domain by calculating
|
|
dEnergy/dTime for that domain.
|
|
|
|
Energy accumulation
|
|
--------------------------
|
|
|
|
Current, Socket energy status register is 32bit, assuming a 240W
|
|
2P system, the register would wrap around in
|
|
|
|
2^32*15.3 e-6/240 * 2 = 547.60833024 secs to wrap(~9 mins)
|
|
|
|
The Core energy register may wrap around after several days.
|
|
|
|
To improve the wrap around time, a kernel thread is implemented
|
|
to accumulate the socket energy counters and one core energy counter
|
|
per run to a respective 64-bit counter. The kernel thread starts
|
|
running during probe, wakes up every 100secs and stops running
|
|
when driver is removed.
|
|
|
|
A socket and core energy read would return the current register
|
|
value added to the respective energy accumulator.
|
|
|
|
Sysfs attributes
|
|
----------------
|
|
|
|
=============== ======== =====================================
|
|
Attribute Label Description
|
|
=============== ======== =====================================
|
|
|
|
* For index N between [1] and [nr_cpus]
|
|
|
|
=============== ======== ======================================
|
|
energy[N]_input EcoreX Core Energy X = [0] to [nr_cpus - 1]
|
|
Measured input core energy
|
|
=============== ======== ======================================
|
|
|
|
* For N between [nr_cpus] and [nr_cpus + nr_socks]
|
|
|
|
=============== ======== ======================================
|
|
energy[N]_input EsocketX Socket Energy X = [0] to [nr_socks -1]
|
|
Measured input socket energy
|
|
=============== ======== ======================================
|