forked from luck/tmp_suning_uos_patched
ec8f24b7fa
Add SPDX license identifiers to all Make/Kconfig files which: - Have no license information of any form These files fall under the project license, GPL v2 only. The resulting SPDX license identifier is: GPL-2.0-only Signed-off-by: Thomas Gleixner <tglx@linutronix.de> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
78 lines
3.0 KiB
Plaintext
78 lines
3.0 KiB
Plaintext
# SPDX-License-Identifier: GPL-2.0-only
|
|
config INTEL_POWERCLAMP
|
|
tristate "Intel PowerClamp idle injection driver"
|
|
depends on X86
|
|
depends on CPU_SUP_INTEL
|
|
help
|
|
Enable this to enable Intel PowerClamp idle injection driver. This
|
|
enforce idle time which results in more package C-state residency. The
|
|
user interface is exposed via generic thermal framework.
|
|
|
|
config X86_PKG_TEMP_THERMAL
|
|
tristate "X86 package temperature thermal driver"
|
|
depends on X86_THERMAL_VECTOR
|
|
select THERMAL_GOV_USER_SPACE
|
|
select THERMAL_WRITABLE_TRIPS
|
|
default m
|
|
help
|
|
Enable this to register CPU digital sensor for package temperature as
|
|
thermal zone. Each package will have its own thermal zone. There are
|
|
two trip points which can be set by user to get notifications via thermal
|
|
notification methods.
|
|
|
|
config INTEL_SOC_DTS_IOSF_CORE
|
|
tristate
|
|
depends on X86 && PCI
|
|
select IOSF_MBI
|
|
help
|
|
This is becoming a common feature for Intel SoCs to expose the additional
|
|
digital temperature sensors (DTSs) using side band interface (IOSF). This
|
|
implements the common set of helper functions to register, get temperature
|
|
and get/set thresholds on DTSs.
|
|
|
|
config INTEL_SOC_DTS_THERMAL
|
|
tristate "Intel SoCs DTS thermal driver"
|
|
depends on X86 && PCI && ACPI
|
|
select INTEL_SOC_DTS_IOSF_CORE
|
|
select THERMAL_WRITABLE_TRIPS
|
|
help
|
|
Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
|
|
temperature sensor (DTS). These SoCs have two additional DTSs in
|
|
addition to DTSs on CPU cores. Each DTS will be registered as a
|
|
thermal zone. There are two trip points. One of the trip point can
|
|
be set by user mode programs to get notifications via Linux thermal
|
|
notification methods.The other trip is a critical trip point, which
|
|
was set by the driver based on the TJ MAX temperature.
|
|
|
|
config INTEL_QUARK_DTS_THERMAL
|
|
tristate "Intel Quark DTS thermal driver"
|
|
depends on X86_INTEL_QUARK
|
|
help
|
|
Enable this to register Intel Quark SoC (e.g. X1000) platform digital
|
|
temperature sensor (DTS). For X1000 SoC, it has one on-die DTS.
|
|
The DTS will be registered as a thermal zone. There are two trip points:
|
|
hot & critical. The critical trip point default value is set by
|
|
underlying BIOS/Firmware.
|
|
|
|
menu "ACPI INT340X thermal drivers"
|
|
source "drivers/thermal/intel/int340x_thermal/Kconfig"
|
|
endmenu
|
|
|
|
config INTEL_BXT_PMIC_THERMAL
|
|
tristate "Intel Broxton PMIC thermal driver"
|
|
depends on X86 && INTEL_SOC_PMIC_BXTWC && REGMAP
|
|
help
|
|
Select this driver for Intel Broxton PMIC with ADC channels monitoring
|
|
system temperature measurements and alerts.
|
|
This driver is used for monitoring the ADC channels of PMIC and handles
|
|
the alert trip point interrupts and notifies the thermal framework with
|
|
the trip point and temperature details of the zone.
|
|
|
|
config INTEL_PCH_THERMAL
|
|
tristate "Intel PCH Thermal Reporting Driver"
|
|
depends on X86 && PCI
|
|
help
|
|
Enable this to support thermal reporting on certain intel PCHs.
|
|
Thermal reporting device will provide temperature reading,
|
|
programmable trip points and other information.
|